Graham’s Family Dairy recalls Graham’s Family Dairy Semi-Skimmed Milk due to the presence of veterinary medicines including antibiotics (penicillin) Medium Product Recall: 32cm Standing Gingerbread Doorstops (2607-0175) Medium Product Recall: Snow White 27cm Standing Gingerbread Doorstops (2607-0177) Medium Product Recall: Wizz Toys 13.5cm Dino Sand Stretchy Racers (2607-0179) Medium Product Recall: Wizz Toys Jumbo Mr Splat Stretch Men (2607-0181) Medium Product Recall: Wizz Toys Squishy Sand Yeti Monsters (2607-0183) Medium Product Recall: Wizz Toys Squishy Puppies (2607-0184) Medium Product Recall: Wizz Toys Squishy Sausage Dog (2607-0186) Medium Product Recall: Haunted House Jumbos and Filled Critters Toys (2607-0185) Medium Product Recall: Wizz Toys 15cm Nana Banana Stress Toy (2607-0009)
Low OPSS electrical

Product Safety Report: Easee One EV Charger Backplate BP-AP-1/s01-01 (2604-0019)

Recall Date: 6 May 2026 Source: OPSS Reference: OPSS-PRODUCT-SAFETY-REPORT-EASEE-ONE-EV-CHARGER-BACKPLATE-BP-AP-1-SLASH-S01-01-2604-0019
🔍 View full details on GOV.UK (OPSS)
Official product safety report including images and corrective action

⚠ What You Should Do

Modification programme. 

Easee have identified affected products using serial number traceability and installer records. Where a mislabelled unit is confirmed to be incorrectly wired and without external PEN protection, charging is temporarily paused until remediation is completed. Where required, corrective actions include inspection, replacement of the backplate and verification by a qualified electrician.

Recall Details

Hazard

The affected units have been fitted with an incorrect three‑phase terminal label. Specifically, the terminal that should be clearly marked as “PME” (Protective Multiple Earthing) is incorrectly labelled as “L3”, which may mislead installers during installation. This incorrect labelling could cause an electrician to connect the PME conductor to the standard PE terminal instead of the dedicated PME terminal, potentially bypassing the charger’s built‑in PEN fault detection and automatic disconnection function required for UK PME installations.

Corrective Action

Modification programme. 

Easee have identified affected products using serial number traceability and installer records. Where a mislabelled unit is confirmed to be incorrectly wired and without external PEN protection, charging is temporarily paused until remediation is completed. Where required, corrective actions include inspection, replacement of the backplate and verification by a qualified electrician.

Why This Product Is Dangerous

The affected units have been fitted with an incorrect three‑phase terminal label. Specifically, the terminal that should be clearly marked as “PME” (Protective Multiple Earthing) is incorrectly labelled as “L3”, which may mislead installers during installation. This incorrect labelling could cause an electrician to connect the PME conductor to the standard PE terminal instead of the dedicated PME terminal, potentially bypassing the charger’s built‑in PEN fault detection and automatic disconnection function required for UK PME installations.