Serious Product Safety Report: Squishy Dumpling D-9373 (2609-0028) High Product Safety Report: Russko Limited Jumbo Duck Mega Squishy (2608-0233) Serious Product Safety Report: XINZHIZHU 42V 2A Charger (2607-0246) Serious Product Recall: Primark Disney 101 Dalmatians Zip Purse (2609-0014) High Product Safety Report: Electronic LED Candle Light (2604-0157) Serious Product Recall: Candle Warmer Lamp sold via TikTok (2606-0188) Serious Product Safety Report: FREESKY Electric Bicycle 540E (2609-0013) Serious Product Safety Report: Vicloon Baby Teether sold via Amazon (2609-0011) Serious Product Recall: Lorelli Silicone Rattle Teether (2606-0257) Medium Product Recall: ONOFF S9 Carbon MTB Handlebars (2609-0008)
Serious OPSS electrical

Product Safety Report: Tucson 5m, 6m and 8m Pumps (2510-0040)

Recall Date: 8 October 2025 Source: OPSS Reference: OPSS-PRODUCT-RECALL-TUCSON-5M-6M-AND-8M-PUMPS-2510-0040
🔍 View full details on GOV.UK (OPSS)
Official product safety report including images and corrective action

⚠ What You Should Do

An installed pump can remain in operation, but you must take care not to handle affected pumps as there is a serious risk of electrocution.  

If you think you have an affected Tucson circulating pump installed in your premises, contact Tucson immediately via email at productsafety@tucsonpumps.ie or phone +(44) 800 044 3258 to arrange for a replacement pump to be installed. The affected pumps can be identified by the serial number (S/N) on the label affixed to the pump as indicated above. The Product Replacement Programme is free of charge. Installed units should only be replaced by an approved Tucson technician or Tucson service agent.  

Homeowners in Northern Ireland who have had heating system work completed or who have moved house within the last 8 years should check if their property contains one of the specified pump models. This is an important safety check that requires immediate attention.

In April 2026, Tuscon Pumps notified additional production periods of Tucson circulating pumps that were introduced to Northern Ireland in the latter half of 2012 and continued to be supplied through to 2016. These serial numbers begin 2012, 2013, 2014, 2015 and 2016.

For further information, please see the Product Safety Information Notice on TucsonPumps.ie.

Recall Details

Hazard

The product presents a serious risk of electric shock. The mains cable can be connected to the pump in reverse, allowing the live pin to connect to the earth pin and causing accessible metal parts to become live.

The product does not meet the requirements of the Electrical Equipment (Safety) Regulations 2016.

Corrective Action

An installed pump can remain in operation, but you must take care not to handle affected pumps as there is a serious risk of electrocution.  

If you think you have an affected Tucson circulating pump installed in your premises, contact Tucson immediately via email at productsafety@tucsonpumps.ie or phone +(44) 800 044 3258 to arrange for a replacement pump to be installed. The affected pumps can be identified by the serial number (S/N) on the label affixed to the pump as indicated above. The Product Replacement Programme is free of charge. Installed units should only be replaced by an approved Tucson technician or Tucson service agent.  

Homeowners in Northern Ireland who have had heating system work completed or who have moved house within the last 8 years should check if their property contains one of the specified pump models. This is an important safety check that requires immediate attention.

In April 2026, Tuscon Pumps notified additional production periods of Tucson circulating pumps that were introduced to Northern Ireland in the latter half of 2012 and continued to be supplied through to 2016. These serial numbers begin 2012, 2013, 2014, 2015 and 2016.

For further information, please see the Product Safety Information Notice on TucsonPumps.ie.

Why This Product Is Dangerous

The product presents a serious risk of electric shock. The mains cable can be connected to the pump in reverse, allowing the live pin to connect to the earth pin and causing accessible metal parts to become live.

The product does not meet the requirements of the Electrical Equipment (Safety) Regulations 2016.

More electrical Recalls